Image of Drummond Nanoject III

Nanoject III Programmable Nanoliter Injector

  • User-Friendly Programmable Touchscreen Operation - Potential Applications Expanded
  • Easy Positive Micropipet Attachments - No O-Rings Required
  • Proven Hydraulic Technology - Ensures Accurate and Consistent Injection Volumes
  • Universal Power Source - Supplied with 4 Interchangeable Adapter Plugs

Nanoject II vs. Nanoject III

Nanoject II FEATURES Nanoject III
3-000-204, 110V Catalog number, 110V 3-000-207
3-000-205A, Euro. Catalog number, European plug 3-000-207
3-000-206A, UK Catalog number, UK plug 3-000-207
2.3 nL-69 nL Injection volumes 0.6 nL-999.9 nL
46nL/sec.& 23 nL/sec. only Rate of injection 1 nL/sec.-200 nL/sec.
No Injection counter Yes
No Programmable multiple injections Yes
No Programmable frequency between injections Yes
No Program storage capability Yes, 8 programs
No Auto HOMING of plunger Yes
3 O-rings, replacement necessary Micropipette attachment No O-rings, new chuck simplifies micropipette attachment
10 µm minimum Micropipette I.D. size 2-3 µm minimum
Yes; inject only Optional Footswitch Yes; fill, empty and inject capability
No; fill, empty, inject buttons only Color Touch Sensitive Keypad Yes; multi screens

Both units utilize the same glass capillaries for pulling micropipettes; however, note that significantly smaller pipettes can be used with the Nanoject III due to the new improved method of securing the micropipette. No O-rings to wear out are used. A micro "chuck" is used that is not a wear item and it simplifies attachment of the micropipette once backfilled with oil.

The auto HOMING feature will eliminate the need to "rehome" the unit as in the Nanoject II and this will reduce if not totally eliminate jamming of the plunger.

The Next Generation in High Precision Nanoliter Microinjection.

The new Drummond Programmable Nanoject III Nanoliter Injector offers a number of state-of-the-art features to provide easy setup and operation as well as more accurate injection volumes down to 0.6 nanoliters. The Nanoject III does not require any O-rings to secure the micropipet. Operational Modes enable the user to program the unit to do single manual injections, as well as multiple injection cycle recipes. Program input and execution is enabled by prompted touchscreens located on the control box. Programmability, the lower injection volume capability plus the user's ability to select the injection rate widens the potential range of applications for the Nanoject III. The Universal Power Source provides adapter plugs to enable the unit to be used in the US, UK, Europe, and Australia simply by inserting the proper plug.

Catalog Information

Cat. No. Description
3-000-207 Nanoject III - Programmable Nanoliter Injector
Power Source - 100/240 volt, 50/60 Hz
Total Sample Volume - 4.2 μL
Fill / Empty Volume Speed - 10 - 200 nL/sec
Injection Volume Range - 0.6 - 999.9 nL
Injection Rate - 1 - 200 nL/sec
Plunger Travel - 23 mm
Glass Micropipette Dimensions - OD 0.045˝ (1.14 mm)
ID 0.021˝ (0.53 mm)

3-000-207 kit contains the following items

Cat. No. Description
3-000-037 Control box & power source
3-000-030-B Injector head
3-000-031 Injector head cable
3-000-203-G/X 100 pcs., 3.5˝ glass capillaries
3-000-203-G/XL 100 pcs., 7˝ glass capillaries
3-000-027 Backfilling needle
3-000-024-A Universal adapter

Accessories not included in kit:

Cat. No. Description
3-000-030-K Replacement collet kit (1 collet, 1 chuck, 1 seal, 1 wire plunger, 1 Allen wrench)
3-000-030-C Replacement collet only
3-000-000-207 Replacement wire plunger (Note: Not the same as the Nanoject II plunger)
3-000-025-SB Support base
3-000-024-R Micromanipulator, right hand
3-000-024-L Micromanipulator, left hand
3-000-032 Footswitch (remote capability for fill, empty and inject functions)

Operation and User Manual:


Nanoject III Programmable Nanoliter Injector

Nanoject Comparison Sheet:


Nanoject Comparison Sheet